<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
<html xmlns:MadCap="http://www.madcapsoftware.com/Schemas/MadCap.xsd" MadCap:tocPath="Using Multiflash|Exchanging data with other programs" MadCap:InPreviewMode="false" MadCap:PreloadImages="false" MadCap:RuntimeFileType="Topic" MadCap:TargetType="WebHelp" lang="en-ca" xml:lang="en-ca" MadCap:conditions="Default.OriginalTopics" MadCap:PathToHelpSystem="../../" MadCap:HelpSystemFileName="Default.xml" MadCap:SearchType="Stem">
    <!-- saved from url=(0016)http://localhost -->
    <head>
        <meta http-equiv="Content-Type" content="text/html; charset=utf-8" /><title>&#160;OLGA</title>
        <link href="../SkinSupport/MadCap.css" rel="stylesheet" />
        <link href="../Resources/Stylesheets/mfwman.css" rel="stylesheet" />
        <script src="../SkinSupport/MadCapAll.js" type="text/javascript">
        </script>
    </head>
    <body>
        <div class="MCBreadcrumbsBox_0"><span class="MCBreadcrumbsPrefix">You are here: </span><span class="MCBreadcrumbsSelf">Using Multiflash</span><span class="MCBreadcrumbsDivider"> &gt; </span><a class="MCBreadcrumbsLink" href="ExchangingData.htm">Exchanging data with other programs</a><span class="MCBreadcrumbsDivider"> &gt; </span><span class="MCBreadcrumbs">OLGA</span>
        </div>
        <h1><a name="kanchor29"></a>OLGA</h1>
        <p class="para">OLGA is a general purpose transient simulator for modelling fluid flow in flow lines and pipeline systems. It is a product licensed by the SPT Group.</p>
        <p class="para">Multiflash can produce a PVT data file for use in OLGA. The file contains all the physical property information required by OLGA. It consists of a series of flash calculations on a grid of pressure and temperature values. The information stored includes all the properties required by OLGA for either two-phase or three-phase problems as set out in SPT Technical Note No. 1. From Multiflash 4.4, the maximum dimension of the temperature and pressure grid has been extended up to 100.&#160; </p>
        <p class="para">To generate the file:</p>
        <p class="para">Define the models (which must include models for surface tension, thermal conductivity and viscosity) and the mixture (components and composition) as usual</p>
        <p class="para">Select <span class="span_3">OLGA</span> from the <span class="span_3">Table</span> menu, then</p>
        <p class="para">
            <img src="../Resources/Images/mfwman/0300010F_391x382.png" style="width: 391;height: 382;" />
        </p>
        <p class="para">Fill in the dialogue box with the pressure and temperature grid points and the name of the output file. The recognised extension for OLGA tables is .tab. This will be allocated automatically if you use the Browse facility to identify a suitable folder and save the file there. Alternatively you can type in the .tab extension as part of the file name. If you want the file saved in a folder directory you must enter the full pathname, otherwise the file will be saved in the current default directory. If the file already exists, the fluid PVT table will be added to the end of the existing file if the append box is ticked, otherwise the entire file will be overwritten with the new PVT table.</p>
        <p class="para">OLGA requires a File id (starting with a letter not a number). If you don't provide one, Multiflash will assign one automatically.</p>
        <p class="para">Click on <span class="span_3">Calculate table</span></p>
        <p class="para">If the file already exists and the append box is not ticked, a warning message will be displayed</p>
        <p class="para">
            <img src="../Resources/Images/mfwman/03000110_371x114.png" style="width: 371;height: 114;" />
        </p>
        <p class="para">Clicking Yes causes the file to be overwritten with the new table. Clicking No means nothing will happen.</p>
        <p class="para">Assuming there are no problems with the calculations the output will go directly to the .named file, it will not be sent to the results window. In the results window you will see the message</p>
        <p class="CodeExplained">Olga&#160;&#160;&#160; table written to file: oil.tab</p>
        <p class="para">Similarly to the Pipesim table option you have the choice of entering the P and T points for the table or specifying ranges and increments or the number of points.</p>
        <p class="para">If any of the input is unacceptable, such as specifying negative pressures or absolute temperatures or if Multiflash cannot solve the flash calculation at any grid point then a warning message will appear. This may be an indication that you have incorrect input</p>
        <p class="para">
            <img src="../Resources/Images/mfwman/03000111_336x118.png" style="width: 336;height: 118;" />
        </p>
        <p class="para">or the calculation routines may fail with the message</p>
        <p class="para">
            <img src="../Resources/Images/mfwman/03000112.png" style="width: 225px;height: 119px;" />
        </p>
        <p class="page_footer">© 2013 - 2014 KBC Advanced Technologies plc. All rights reserved.</p>
        <script type="text/javascript" src="../SkinSupport/MadCapBodyEnd.js">
        </script>
        <p class="MCWebHelpFramesetLink MCWebHelpFramesetLinkBottom"><a href="../../Default_CSH.htm#Using_Multiflash/OLGA.htm" style="">Open topic with navigation</a>
        </p>
    </body>
</html>