Previous Icon 3

Next Icon 3

Estimating the strength of asymmetrical spur gear toothings

At present, KISSsoft does not have any algorithms that can be used to perform a direct strength calculation for asymmetrical gears. Safeties are determined using the calculation methods in ISO 10300 for hypoid gears (hypoid teeth are asymmetrical, and have an unequal pressure angle on the right-hand and left-hand flank).

This procedure is described below:

The calculation is run twice, each time with a symmetrical tooth, once with a high pressure angle (calculation I), once with small pressure angle (calculation II).

The safety factor for the required safety against pitting that corresponds to the calculation with the flank under load is applied here. Therefore, if the load flank is the one with the small pressure angle, the safety against pitting from the calculation with the smaller angle (SHII) is used.

Root safety is determined with the nominal stress (tooth form factor YF), which is derived from the loaded flank. The tooth thickness at root sFn is determined from both these calculations, so therefore:

sFn = (sFnI + sFnII)/2