34. Clamped connections
Clamped connections are only used to transfer low or medium torque (little fluctuation).

Figure 34.1: Basic data: Clamped connections
There are two different configurations of clamped connections that can be calculated:
In the case of a split hub, it is assumed that pressure is distributed uniformly across the whole joint. The pressure can be equal or cosine-form surface pressure or linear contact.
We recommend you use as narrow a fit as possible (hubs are also subject to bending) to ensure that the pressure is mostly of a linear nature. The calculation is performed for the least practical case of linear pressure.
Calculations of safety against sliding and surface pressure are described in literature by Roloff Matek [62]. The calculation of bending is performed as specified by Decker [86].