Short and long linear drives subjected to pressure are handled separately in the calculation process.
Short pressure stressed drive screws
Short pressure stressed drive screws are not at risk of buckling and therefore are not tested for this.
The required cross section of the thread can therefore be defined using the formula:

σd(z)zul: under static load: Rp/1.5; under pulsating load σ zdSch/2.0; under alternating load: σ zdW/2.0;
Long pressure stressed drive screws
The formula for calculating the necessary core diameter of the thread is taken from the Euler equation:

S: Safety (S6 to 8)
lk: mathematical buckling length, lk 0.7*l (Euler buckling case 3 used for general, guided spindles)
Calculation of the strength:
Load case 1:
The upper part of this configuration is subject to torsion and the lower part is subject to compression and therefore buckling.
Torsional stress:

Wp: polar moment of resistance Wp0.2*d3^3
τtzul: permissible torsional stress; static load τtF/1.5; pulsating load τtsch/2.0; alternating load τtW/2.0;
Compressive (tensile) stress:

A3: Thread minor diameter cross section
σd(z)zul: permissible compressive (tensile) stress
Load case 2:
The upper part of this configuration is subject to torsion and the lower part is subject to compression, infrequent tension and torque.
Formula for the part to be checked:
![]()
The required torque corresponds to the thread torque, if not subject to any moments of friction.
![]()
d2: Flank diameter of the thread
φ: Lead angle of the thread (for single thread trapezoidal screws φ3°...5.5°)
ϱ': Thread friction angle

Figure 61.3: Values for the friction angle
The + in the formula stands for "tightening the spindle", and - stands for "loosening the spindle". The KISSsoft procedure calculates both situations and outputs the results in a report.
Calculation for buckling (only for long spindles):
First of all, calculate the slenderness ratio.

λ: Slenderness ratio of the spindle
lk: mathematical buckling length
i: Gyration radius
Only 3 different materials can be used for the spindle so that the slenderness ratio can be defined correctly.
Elastic buckling is present if λ>=λ0 = 105 for S235; λ>=89 for E295 and E335.

The non-elastic area as defined by Tetmajer and l λ<105 for S235.
![]()
For λ<89 and for E295 and E335:
![]()
For a non-elastic case, the Johnson parabola equation can also be used for the calculation. (also for other materials)

The safety can then be calculated as follows:

The required safety for elastic buckling is Serf3 to 6. For non-elastic buckling, it is Serf4 to 2.
Buckling no longer needs to be calculated for a slenderness ratio < 20.
Analysis of the nut:
The surface pressure of the nut is calculated from the nut length:

P: Pitch of thread
l1: Length of the nut thread
d2: Flank diameter of the thread
H1: Flank engagement of the thread
pzul: permissible surface pressure
Due to the uneven distribution of surface pressure, the nut length should be no greater than 2.5*d. During sizing, the length is limited to 2.5* d even if a longer one is input.
Efficiency and self-locking:
The efficiency of the conversion from rotational movement into longitudinal movement:

The conversion of movement is only possible for non-self-locking threads, because the limiting value in this case is that, if φ=ϱ', the efficiency is 0.5.
If φ>ϱ', the thread is no longer self-locking.
Each permissible value is taken from the Roloff Matek tables.