Load spectra
All inputs (frequency, power, speed) must be defined in factors. The power and speed are given as factors of the nominal power. In the calculations, the factor for torque (load factor/speed factor) is used for forces and moments. You can either import load spectra from a file or enter them directly. If you input this data directly, the number of load cases is defined by the number of lines you enter.
- Input: Specify whether the factors are for power or torque. This also applies if the load spectrum is imported from a file.
- Link with file: This option is displayed if the load spectrum is set to "Own input". If the option is displayed, load spectrum values can be imported from a selected file. The import can be performed in two ways: If the flag is not set, the imported load spectrum values can be modified. If the flag is set, the load spectrum values are automatically overwritten by the values in the selected file, and cannot be modified.
- Own input of load spectra: You can input the load spectrum directly, or import it from a file.
- File name: Click the
button to select a file from the directories. The file containing the load spectrum must be a text file (*.dat). You will find a sample load spectrum file (called "Example_DutyCycle.dat") in the "dat" directory. You should store load spectra you define yourself in the "EXT/dat" directory to ensure they are always available even after a version upgrade.

Example of a file used to input a load spectrum
- Frequency: H0 ... H19, the sum of these frequencies must be 1.
- Load factor (torque factor): P0 ... 19 0<Pn<,∞.
- Speed factor: N0 ... N19, 0<Nn<∞.
Load bins with negative power or speed are interpreted as a change from driving to driven. This does not affect the root and flank strengths, however it does change the scuffing safety and safety against micropitting.