Previous Icon 3

Next Icon 3

Calculating spline connections according to DIN 5480 with diameter centering

In the case of flank-centered connections, the flanks are used for centering and rotational synchronization. The nominal lengths of the root diameter used for the shaft and the hub in flank-centered connections are the "theoretical root diameter" calculated with hfP = 0.55*m. All reference profiles without the note Major diameter fit or Minor diameter fit are for flank-centered splined joints.

The allowances that apply where chip-producing manufacturing processes are involved cover the corresponding greatest possible dedendum (hfP=0.65*m) and the root diameter allowances. The tolerance field for the root diameter of the tooth space is 9H. For the hub root diameter it is 11a.

The following values apply for flank-centered splines:

This description is for calculating the root circle tolerances in accordance with the base standard, DIN 5480-1, Table 5.

Click on Calculations/Settings/General to select whether root circle tolerances are to be calculated according to the manufacturing process (DIN 5480-16, 4.3.1) or according to the base standard (DIN 5480-1, Table 5).

When the root circle tolerances are calculated according to the basic standard DIN 5480-1 (table 5), the root form diameter is calculated as specified by the formulae on page 13:

Shaft root form circle diameter: dFf1 = |da2| - 2*cFmin

Hub root form circle diameter: dFf2 = -(da1 + 2*cFmin);

cFmin comes from Table 4 in the DIN 5480-1 standard.

If either the reference diameter or the module lie outside of the defined range, the adjacent edge value in the table is used as cFmin.

The tolerance band calculated for the root diameter is also used here.