Bolted joint under axial and shearing force

In the second configuration, the required clamp load for axial load transmission is calculated from the shearing force FQ, the torque MT , the coefficient of friction mT , the diameter da and the number of force transmitting parting lines qT:

 

(42.5)

(42.6)

 

FKQ

Required clamp load for transferring a shearing force and/or a torque through friction grip (e.g. for friction grip)

FKP

Clamp load required to guarantee a sealing function (required when internal pressure is present)

μT

Interface coefficient of static friction (when shearing force or torques are present), → see Figure.

ra

Friction radius resulting from the dimensions of the clamped parts where the torsional moment is acting