The forces on the single bolt in the case of flanged joints (with stress from torque and/or shearing force and/or bending moment and/or axial force) are calculated according to [63], and also partially according to [61], Example 8.4:
|
(42.7) |
|
(42.8) |
|
(42.9) |
|
(42.10) |
|
(42.11) |
dt |
Bolt pitch diameter |
n |
Number of bolts |
μT |
Coefficient of friction between the parts, see Figure 42.3 |
FQ |
Shearing force on configuration |
FAmax |
Axial force on configuration (maximum) |
FAmin |
Axial force on configuration (minimum) |
FBo |
Upper limiting value |
FBu |
Lower limiting value |
FKP |
Configuration sealing load |
MB |
Bending moment on configuration |
MT |
Torque on configuration |
FKerf |
Required clamp load |
FKQ |
Required clamp load (e.g. for friction grip) |
FKP |
Required clamp load to ensure sealing (atinternal pressure) |
FKA |
Required clamp load to prevent gaping under eccentric load |
If you select a flanged joint configuration, we strongly recommend that you define the geometry of the clamped parts as . The program then automatically generates proposed values for the pitch (t) and the bolt radius of the annulus (rs).
Experience shows that the results of VDI 2230 are usually very conservative for flanged connections. In order to achieve realistic results, you should increase the coefficient of friction between the parts.

Figure 42.3: Interface friction grip coefficients according to [75]