Uncertainties such as, for example, the scatter of coefficients of friction, differently precise tightening techniques, instrument, operating and reading errors result in the scatter of the achievable assembly pretension force. For this reason, oversizing the bolt is necessary, and is expressed by the tightening factor αA = FMmax/FMmin. If the required minimum pretension force FMmin remains constant, then an increasing tightening factor αA means that the bolt must be sized for a greater maximum assembly pretension force FMmax (due to the greater scatter). Tightening technique and associated tightening factors:
Tightening factor αA |
Tightening technique |
Adjusting technique |
1.0 |
Yield point-determined |
|
1.0 |
Angle of rotation-controlled |
Experimental determination of the preload moment and angle of rotation |
1.2 to 1.6 |
Hydraulic tightening |
Adjustment by means of measuring length or pressure |
1.4 to 1.6 |
Torque-controlled tightening with a torque wrench, torque indicating wrench or a precision torque wrench with dynamic torque measurement |
Experimental determination of the required tightening torques on the original bolting part, e.g. by measuring the length of the bolt |
1.6 to 1.8 |
ditto |
Defining the nominal tightening torque by estimating the friction factor, value (surface and lubrication ratios) |
1.7 to 2.5 |
Torque-controlled tightening with a bolt installation spindle |
Torque wrench adjustment with a tightening-up moment, set to the required tightening moment (for an estimated friction factor, value) plus a supplement. |
2.5 to 4 |
Pulse-controlled tightening with an impact wrench |
Torque wrench adjustment with tightening-up moment as described above |