Load application

The VDI guideline issued in 2014 defines equations for calculating the load application factor. Here, you must select a configuration in accordance with Figure 42.13. The interface must lie within the range shown in gray. The length of the clamped parts h, the distance to the connection piece akand the length of the connected solid lA as shown in Figure 42.14 define the position of the application of load point and therefore also the load application factor.

In single-bolted (tapped thread) connections, only configurations SV1, SV2 and SV4 are available. You must use the height hESV up to the interface as the height h.

Figure 42.16: Configurations for defining the load application factor as shown in VDI 2230 (2015 edition).

 

Figure 42.17: Inputs for defining the load application factor as shown in VDI 2230 (2015 edition).