Previous Icon 3

Next Icon 3

Input the Constraints data

In this calculation, you can define the yield point utilization, the maximum assembly pretension force or both tightening torques as constraints. If you define the maximum and minimum tightening torque as constraints, the tightening factor is then calculated from this torque variation and the friction coefficient variation. You can also enter values for the number of load cycles, amount of embedding, preload loss and temperatures for the bolted joint in this window.

Figure 42.18: Preset values, ready for input.

 

Use of the yield point
In usual bolt layouts, the bolt is tightened to 90% of its yield point to calculate the pretension force. However, if you use yield point or angle of rotation-controlled tightening, you can increase this utilization value up to 100%.

Number of load cycles
If this number of load cycles is ND >= 2*106 the fatigue lives for final heat treated and final rolled bolts are calculated in accordance with the formulae specified in VDI (VDI 2230, 5.5/20 and 5.5/21). If smaller values are involved (ND < 2*106), a limited life fatigue strength sizing is performed for the connection (5.5/22 and 5.5/23).

Amount of embedding

The amount of embedding is calculated according to which calculation method you use. You can also input an extra amount of embedding value for flat seals. In addition, you can overwrite the calculated amount of embedding with your own value or input the preload loss directly. If you input your own preload loss, the amount of embedding is no longer taken into account.

Assembly and operating temperature
Now KISSsoft's bolt calculation function has been extended, it can be used for the calculation guideline specified in VDI 2230, which also calculates bolted joints for operating temperatures between -200 and +1000 degrees Celsius. You can specify different temperatures for the bolt and the clamped parts (connecting solids). You can also take into account the temperature-dependent changes of the Young's modulus, the thermal expansion coefficients, the yield point and the pressures permitted for the materials. You can either use empirical formulae to calculate these temperature-dependent values, or specify your own values. Since the empirical formulae for steel have already been determined, you should check the values for high-temperature changes or, even better, enter your own values here.

All the criteria for the bolted joint are checked in the assembled state at ambient temperature, and also in a stationary or non-stationary state at operating temperature (according to VDI 2230: pretension force, bolt load, fatigue life, and surface pressure).

KISSsoft automatically performs the calculation for assembly and operating temperatures at the same time. This calculation should also be performed for a higher temperature difference between the bolt and the parts. The minimum temperature difference between the parts or the bolt and the assembly temperature must at least equal 30o C, so that results appear in the report.

Siehe auch

Technical Explanations

Coefficient of friction

Rotation-angle controlled tightening