Click on the flag to calculate the length of engagement and check the stripping strength of the thread according to VDI 2230 section 5.5.5.

Figure 42.21: Entries for calculating the length of engagement and stripping strength
In this screen you can enter the data for the length of engagement. Use the sizing buttons to set the individual defaults which were calculated from the entries in the main screen.
The length of engagement meffmin is calculated from the (theoretical) tensile strength Rm of the bolt material, the length of engagement meffmax is calculated for the bolt and internal thread (with Rmmax, dmin or d2min and D2max or D1max according to VDI 2230 Sheet 1, Equation 210/213). The more critical case is then displayed in the results.
The default value for the Rmmax/Rm coefficient is 1.2. This is also stated as a practice-related value in VDI 2230.
You can change the Rmmax/Rm coefficient in .
To calculate the worst case (VDI 2230, formula 210), you must also take the thread tolerance into account. To define this influence, the minimum external diameter of the bolt dmin, the maximum flank diameter of the internal thread D2max, the minimum flank diameter of the bolt thread d2min and the maximum core diameter of the internal thread D1max can be entered in this window.
The main report lists the stresses, the minimum length of engagement, and the safety against shearing under load, with the maximum pretension force for the connection.