Figure 33.7: Settings: Conical interference fit

If you selected Calculate material strength with wall thickness as raw diameter, the strength of the hub material is calculated using the wall thickness instead of the raw diameter.

If you select the Consider pressure at both diameters (Kollmann) flag, the pressure at both the large and small cone diameters is taken into account, otherwise only the pressure at the largest diameter is used. However, this only applies to the method described by Kollmann. In DIN 7190-2, the average diameter is used for the calculation.

Enter the required safety factor for slipping and yield point under Settings. These safety factors are then used to define the values you require during sizing.

In the method defined by Kollmann, the default value set for required safety against sliding is 1.0 and the default value for required safety against the yield point is set to 2.0.

DIN 7190-2 recommends that safety against the yield point should be set to 1.2 to ensure that the elements are not affected by plastic flow when they are disassembled hydraulically.

In the case of a central load application, DIN 7190-2 recommends a safety against sliding of at least 1.2.