Settings

Figure 32.5: Settings: cylindrical interference fit
- Select equivalent stress
According to [64], with the modification of shape hypothesis:

- According to [55], page 13, with the shearing stress hypothesis:
σv = max(|σ
σrr|,|σ
σrr|)
The press-on force can be calculated from the assembly temperatures.
Here you can define the μeμa ratio, i.e. the ratio of the coefficient of friction for press on to the axial coefficient of friction. The default value is 1.3.
Only values for forcing off are given in DIN 7190. Niemann Volume I (1981 edition), Table 18/3 p. 363, also gives values for this press on.
Here you can define the μeμa ratio, i.e. the ratio of the coefficient of friction for forcing off to the axial coefficient of friction. The default value is 1.6.
Only values for forcing off are given in DIN 7190. Niemann Volume I (1981 edition), Table 18/3 p. 363, also gives values for this press on.
The mounting clearance can be input as either dependent on the diameter of joint DF (modified for warming) or as a constant mounting clearance. The joining temperature of the external component is then calculated from this value.
You can also define the shaft temperature for joining. This temperature and the mounting clearance are then used to calculate the joining temperature of the hub. The joining temperature of the hub is only output in the report
if the shaft temperature during joining lies between -273 °C and 20 °C.-
Under Settings you can input the required safeties against sliding, yield point and fracture. These safety factors are then used to define the values you require during sizing. The required safeties against plastic deformation are used to define the plasticity diameter that must be set when an interference fit is placed under plastic-elastic stress.
If you set this flag, the strength of the hub material is calculated using the wall thickness instead of the raw diameter.
If you set this flag, the calculation is also performed for elastic-plastic stress (according to DIN 7190), otherwise, only elastic stress is included.
If there is a negative allowance during operation, an error message is displayed. This usually interrupts the calculation, because this value means the fit is no longer an interference fit. Set this flag to force the calculation to continue despite the error message so that you can display allowances for higher operating temperatures. Only the section with the allowances calculated for operation are then displayed in the report.