Essentially, both calculation procedures are based on the equation used to ascertain the thermal balance in the bearing. You can use either convection or circulatory lubrication in this calculation.

Figure 30.4: Segment lubricant and heat levels
These calculations provide values for the friction power, the lowest lubricant film thickness and the operating temperature. For circulatory lubrication, they also calculate the lubricant flow rate.
The bearing force (in standstill) is only used to determine the lowest admissible lubricant film thickness, and is otherwise irrelevant. The value of the load coefficient, the friction coefficient, and the lubrication flow rates are calculated according to the formulas (not according to the diagram or table) stated in DIN 31653/ 31654 Part 2. For tilting-pad thrust bearings, the ratio hmin/Cwed is calculated from the support position of the tilting-pad aF*. The formula for this is given in ISO 12130 Part 2 or in DIN 31654 Part 2.