Strength calculation according to R. Hänchen and H. K. Decker [42] is an old, but well established method. If insufficient notch factor data is present, the equations produced by TÜV in Munich, Germany, are used: they are derived from known test results.
As shown in Figures 52, 56 and 60 according to [42] for construction, heat treated and case hardening steels. The empirical formula used is according to Hänchen [42], page 37
![]()
You can enter the material data in the database.
In the case of bending and torsion, KISSsoft calculates the equivalent stress value σV in accordance with the hypothesis of the largest distortion energy (see [42], section 3.2.5.).
A)= Comparative stress (fatigue stress)
|
25.1) |
|
25.2) |
|
25.3) |
A1) Comparative stress (strength against overload failure and deformation (τt = 0)
|
25.4) |
|
25.5) |
|
25.6) |
B) Calculation of the safety against fatigue failure:
|
25.7) |
|
25.8) |
α0 |
a.0 |
Stress ratio factor |
|
A |
A |
Cross section area |
(cm3) |
bd |
b.d |
Thickness number |
|
bkb |
b.kb |
Notch factor (bending) |
|
bo |
b.o |
Surface number |
|
f |
f |
Total load factor |
|
Fq |
F.q |
Shearing force |
(N) |
Fz |
F.z |
Tension/Compression force |
(N) |
Mb |
M.b |
Bending moment |
(Nm) |
Mt |
M.t |
Torque |
(Nm) |
σb |
s.b |
Bending stress |
(N/mm2) |
σbW |
s.bW |
Fatigue strength under reversed bending stresses |
(N/mm2) |
σbWG |
s.bWG |
Deformation strength under reversed bending stresses |
(N/mm2) |
σv |
s.v |
Equivalent stress |
(N/mm2) |
SD |
S.D |
Safety against fatigue failure |
|
τq |
t.q |
Shear stress (shearing force) |
(N/mm2) |
τt |
t.t |
Torsional stress |
(N/mm2) |
Wb |
W.b |
Axial moment of resistance |
(cm3) |
Wt |
W.t |
Polar moment of resistance |
(cm3) |
You will find values for the stress ratio factor in Table 25.2.
Bending |
alternating |
alternating |
static |
static |
static |
static |
Torsion |
pulsating |
alternating |
pulsating |
alternating |
static |
static |
Structural steel |
0.7 |
0.88 |
1.45 |
1.6 |
1.0 |
1.0 |
Case hardening steel |
0.77 |
0.96 |
1.14 |
1.6 |
1.0 |
1.0 |
Through hardening steel |
0.63 |
0.79 |
1.00 |
1.6 |
1.0 |
1.0 |
Table 25.2: Stress ratio factor α0 according to Hänchen page 28 [42] or Niemann, I, page 76 [64]