The structural factor takes into account differences in materials and heat treatment at scuffing temperature. Structural factor XwrelT (in DIN 3990 and in ISO TR 13989-2) or structural factor Xw (in ISO TR 13989-1) is used, depending on which standard is used. However, in this case, XwrelT = Xw/XwT and XwT = 1 applies. This results in XwrelT = Xw. The two factors are identical.
However, the standards do not provide any details about how to proceed when different types of material have been combined in pairs. You must input this factor, yourself because it is not set automatically by KISSsoft.
Through hardened steels |
1.00 |
Phosphated steel |
1.25 |
Coppered steel |
1.50 |
Nitrided steel |
1.50 |
Case-hardened steels |
1.15 (with lower than average austenite content) |
Case-hardened steels |
1.00 (with normal austenite content) |
Case-hardened steels |
0.85 (with high austenite content) |
Stainless steels |
0.45 |
Table 14.9: Structural factor as defined in DIN 3990, Part 4
The standard does not provide any details about how to proceed when the pinion and gear are made of different material types. In this case it is safer to take the lower value for the pair.