As specified in AGMA 925, you can use this input window to define the probability of scuffing and wear as well as susceptibility to micropitting (frosting).

Figure 14.57: input window
AGMA 925-A03 Effect of Lubrication on Gear Surface Distress calculates the conditions in the lubrication gap across the gear meshing. AGMA 925 defines how to calculate the lubrication gap height while taking into account the flank deformation, lubricant properties, sliding velocity, and local Hertzian stress. The standard then uses this base data to calculate the probability of wear. The wear is caused by the metal surfaces contacting each other if the lubrication gap is too narrow. The probability of wear calculated by the standard is greater than the values that occur in practice.
The standard does not give any indications about safety against micropitting (frosting). However, data provided by the relevant technical literature, and the results of research, reveal that there is a direct correlation between the minimum lubrication gap-to-surface roughness ratio and the occurrence of micropitting (frosting). You can therefore use this calculation method to optimize gear toothing for micropitting (frosting). AGMA 925 also includes a definition of the probability of scuffing. This analysis uses the same base data (Blok's equations) as the calculation of scuffing according to the flash temperature criteria given in DIN 3990, Part 4. However, defining the permitted scuffing temperature according to AGMA 925 presents more of a problem, because of the lack of comprehensive or generally applicable information. In particular, there is no reference to a scuffing load capacity specification as given in the FZG test. There is therefore a tendency to underevaluate oils that have effective EP additives.
The values for the compression viscosity coefficient α of typical gear oils vary between 0.00725mm2/N to 0.029mm2/N, and are defined as follows in AGMA 925-A03:
|
(14.25) |
where
α |
Compression viscosity coefficient |
mm2/N |
k |
see Table 2 in AGMA 925-A03 |
- |
ηM |
Dynamic viscosity for tooth temperature θM |
mPa . s |
In practice, calculating wear in accordance with Wellauer results in risk of wear values that are too high. For this reason, the analysis is performed according to Dowson (as in Annex E of AGMA 925). The report shows the results for both methods.