Example: Interference fit calculation

The following example of the Interference fit assembly calculation is used to illustrate the way that the KISSsoft interfaces concept works, in more detail.

For the interference fit assembly between the gear rim and the cylindrical gear hub, you need to find the one tolerance pairing that meets the following constraints:

Permanent torque MD = 88000 NM

The tolerance pairing involves a system of the standard drill hole (H) .

Safety

against sliding > 1.4

 

against fracture of the wheel or hub > 1.5

 

against fracture of the gear rim > 1.5

 

against the yield point of the hub > 1.1

 

against the yield point of the gear rim > 1.1

Procedure:

The necessary information for the geometry will be extracted direct from the drawing, with a suitable CAD routine, and converted into the interfaces format defined by KISSsoft:

 

m01allg.df=640

 

m01n.da=800

 

m01w.di=242

 

m01allg.l=200

Content of the M010USER.INI file

Then, start the KISSsoft module. It accepts the geometry data and displays it in the main screen.

In the main screen, enter any parameters that are still missing, the torque, and the materials, and then start the calculation. In KISSsoft, you can also size the tolerance pairing. Here, you are prompted to select the suitable tolerance combinations from a list. The system then performs the calculation with your final selection.

After you have finished the calculation, the results file is automatically converted to a format that can be read via the CAD macro. The format of this result file is defined via the templates file, M010USER.RPT:

[SHAFT]

ntol_max = %f{m01w.tol.max}

ntol_min = %f{m01w.tol.max}

ntol_bez = %s{m01w.tol.bez}

[HUB]

ntol_max = %f{m01n.tol.max}

ntol_min = %f{m01n.tol.max}

ntol_bez = %s{m01n.tol.bez}

Content of the M010USER.RPT file

The result has then following appearance:

[SHAFT]

wtol_max = 390.000000

wtol_min = 340.000000

wtol_bez = s6

[HUB]

ntol_max = 50.000000

ntol_min = 0.000000

ntol_bez = H6

Content of the M010USER.OUT file

Via the macro, this data will now be attached directly to the appropriate dimension in CAD.

Summary:

The individual tasks are therefore split up: Each side of the interface will perform only the tasks it is best suited to. The CAD administers the geometry and passes this information on to the calculation program, which knows how to process the data, and which, in turn, will return the result to the CAD.

The CAD system and calculation program can be used efficiently, in combination, with the defined interface.