Convert external pressure with multiple interference fit
The effect of outside pressure on the first hub can be taken into account for a multiple interference fit. This pressure is defined through a series of sequential interference fits, as shown in the following figure, and is calculated by the software (no direct user input).

Figure 32.3 Multiple interference fit
The following notes apply to this calculation:
- The first two elements are the original shaft and hub (the first two lines in the table correspond to the first interference fit on the shaft), and are just shown in the table for the sake of completeness. The only user-editable values are the external diameter tolerances of the hub.
- The external diameter of each ring also serves as the inside diameter of the next ring.
- When a new ring is added the following default values are used:
- External diameter = inside diameter + 50 mm
- The Material and Roughness are those of the original hub
- The operating temperature is the same as that for the hub
- The tolerance class of the inner diameter is the same as the tolerance class of the shaft (for example, s6)
- The tolerance class of the external diameter is the same as the tolerance class of the hub (for example, H7)
The pressure on the hub is calculated for the following three cases of tolerance values of all elements:
- The average tolerance at each contact surface
- The worst case, i.e. the maximum oversize at each contact surface
- The best case, i.e. the minimum oversize at each contact surface