Conditions III

Figure 15: tab in the window
You can define more parameters in the tab.
- 1. Show values of KISSsoft main calculation as additional variant with number 0
- The toothing data displayed in the KISSsoft Basic tab can also be displayed as a variant with number 0 (table and
- graphic). However, the data at the start of the fine sizing process must be consistent before this can happen.
- 2. Calculate geometry only
- If you select this method, no strength calculation is performed
- 3. Strength calculation with load spectrum
- Before you can perform calculations with a load spectrum, you must set a load spectrum in the main KISSsoft window BEFORE starting fine sizing,
- and run the load spectrum calculation once (to ensure the data is consistent). In this case, when you start the fine sizing process,
- you are prompted to confirm whether the calculation is to be performed with a load spectrum. The flag in the window only shows whether (or not) a load spectrum is being used.
- You cannot change the flag.
- 4. Suspend results which do not meet required safety factors
- Variants which do not meet the predefined minimum safety levels (see ) will be
- rejected.
- 5. Transmission error
- If the "Calculation of the transmission error" option is selected, contact analysis is performed for every variant.
- During the contact analysis for transmission error, the default settings, except for the coefficient of friction, and accuracy, are used to prevent the calculation
- from behaving in any unusual way. Input the settings in the main program, in the "Contact analysis" tab. You can also
- specify the accuracy of the calculation. However, we strongly recommend you select "medium" or "low" to reduce the processing time. Therefore,
- the transmission error in fine sizing may not be exactly the same as you get in the contact analysis, depending on the
- selected settings.
- The default values are as follows;
- Calculation for: right flank
- Torque for gear A: not considered
- Torque for gear B: not considered
- Partial load range for calculation: 100 %
- Center distance: Mean center distance allowance
- Single pitch deviation: 0 mm
- Then, the results list shows;
- Transmission error (PPTE)
- Medium wear on the tooth flank (delwn1, delwn2)
- Maximum flash temperature (theflamax)
- Variation in bearing force (VarL)
- The calculation time increases significantly with the transmission error calculation option. For this reason, we recommend you limit the number of variants to be calculated
- before you start the calculation