Previous Icon 3

Next Icon 3

Heat treatment of hollow shafts in the full state

If you do not input the raw diameter for a "heat treatment state", and you are investigating a hollow shaft (di > 0.1*da), you can use this option to specify

whether the coefficients are determined using the solid shaft or hollow shaft. This option is only valid for the FKM and DIN calculation methods.

Table 1.2.3 in the 6th Edition of the FKM Guideline shows data for both a hollow shaft and a solid shaft, and also methods for Case 1 and Case 2. Case 1 is for parts made of treated steel, case hardening steel etc., Case 2 is for parts made of unalloyed steel, normally annealed through hardening steel, etc. KISSsoft automatically calculates values for these 2 cases when you input the material.

According to DIN 743-2, the shaft diameter is used as the deff for coefficients K2 and K3. If a solid shaft is involved, the diameter is used for coefficient K1. If a hollow shaft is involved, the wall thickness s or 2* the wall thickness is used for deff, according to FKM.