Load cases
In the endurance limit diagram, different assumptions are used to determine different levels for the maximum stress amplitude SAK. Assumptions where sm=const. result in a larger SAK than for R=const. This is because the limit lines in the Smith diagram rise by an angle < 45o (mean stress sensitivity). The most suitable assumption depends on the expected change in stresses in the part when it is subjected to permitted operational fatigue load. The overload case can therefore be a decisive factor in whether or not a part is overloaded [62].
Load case
- Type of overloading F1 (constant mean stress): at a constant mean stress, the stress amplitude increases as the decisive operating force increases.
- Type of overloading F2 (constant stress ratio): when the operating force increases, the ratio between the maximum stress and minimum stress remains the same. This overload case usually returns conservative results (compared to other overload cases) and should therefore be used in case of doubt.
- Type of overloading F3 (constant minimum stress): when the operating force increases, the minimum load remains the same.
- Type of overloading F4 (constant maximum stress): when the operating force increases, the maximum load remains the same.