Application factor and summand for operational behavior

You can either enter the application factor manually in the load factor interface, or have the program define it from the operating parameters. If you selected a configuration with a tensioning pulley, you must increase the operating factor by 0.1. Use the data in this table to define the factor (refer to the catalogs for more information):

Driven machine

Operating hours per day

 

0-10

10-16

16-24

Light drive

1.2

1.3

1.4

Medium-light drive

1.4

1.5

1.6

Medium-heavy drive

1.5

1.6

1.7

Heavy drive

1.7

1.8

1.9

Heavyweight drive

1.8

1.9

2.0

Table 53.3: Application factors 

Summand for operational behavior
(This summand is added to the operating factor in the calculation)

Operational behavior:

Summand

continuous, 0-10 hr/day

0

continuous, 10-16 hr/day

+0.1

continuous, 16-24 hr/day

+0.2

intermittent or with alternating load

-0.1

Table 53.4: Summand