Influence factors
When calculating individual connections you must include a number of influencing factors which are defined depending on the load, stress, type, etc.:
- Application factor
- Dynamic factor:
fixed load: Cd = 1; pulsating load: CD = 0.7; alternating load: CD = 0.5;
for coiled spring pins and spiral pins (bushes)
fixed load: Cd = 1; pulsating load: CD = 0.75; alternating load: CD = 0.375; - Reduction factors for full/grooved dowel pin
Full pin: CK = 1; grooved dowel pin (bending, shear): CK = 0.7; grooved dowel pin pressure: Ckp = 0.8;
Since the permissible stress values in the literature are very low, other material factors have been added to obtain the values in the table.