Previous Icon 3

Next Icon 3

Permissible pressure

The permitted values are calculated on the basis of the yield point (or fracture in the case of brittle materials). For continuous stress with Teq:

- for ductile materials:
peq=fs * fH * Rp

- for brittle materials:
peq=fs * Rm

 

Structural steel

Material

fs

Shaft

Structural steel, through hardening steel, case-hardened steel, GJS, GS

1.2

 

GJL

1.0

Hub

Structural steel, through hardening steel, case-hardened steel, GJS, GS

1.5

 

GJL

2.0

Table 37.6: Support factor as specified by Niemann

 

The support factor fs takes into account the support effect that appears in components subjected to a compression load.
The hardness influence coefficient, fH, is derived from the ratio of surface to core hardness for surface hardened components.
The hardness influence coefficient for case-hardened steel is 1.15. Otherwise, it is 1.0. The values used for this coefficient are defined in DIN 6892.

For calculation with peak torque:

pmax=fL * peq

fL is the frequency of load peak factor, which depends on the material type and the frequency of load peak. This coefficient is shown in a diagram in DIN 6892.