35. Key
Keys are by far the most commonly used shaft-hub connections. In particular, they help to transmit the torque. Their geometry has long been standardized according to DIN 6885 [26]. However, to ensure adequate safety levels were achieved when transmitting torque, it was always necessary to refer to secondary sources of technical literature [64]. DIN standard 6892 [27] documents the different calculation methods that can be used for key connections.
You must perform two checks for keys:
- Check the torque transmission by monitoring surface pressures on the shaft, hub and key.
- Check the fatigue limit of the shaft due to the notch effect caused by the keyway. This effect is already described in DIN 743 [9]. We recommend you use this standard to verify the shaft strength, rather than DIN 6892.
Special characteristics of calculations according to DIN 6892:
- Key connections are mostly used with light interference fits. The calculation takes into account the decrease in torque on the key due to the interference fit.
- The calculation proves the nominal torque as well as the actual pitch torque over the entire operating period. The fatigue strength calculation based on the nominal torque also includes the number of load changes, which experience has shown to have a significant and damaging effect on the key.
- The type of load has a considerable effect on the service reliability of keys. This effect is taken into account by using a wide range of load distribution coefficients.
- The permissible pressure values are derived from the yield point. As a result, you can derive this for common and more unusual materials in accordance with the standard. The hardness influence coefficient is used to take the surface treatment into account.
Calculation Method B as defined in DIN 6892 recommends you use a differentiated calculation to prove the service reliability of key connections. Method C has been greatly simplified.