Use this module to calculate the service reliability of a conical interference fit. Defining the mounting conditions.
The calculation methods are:
- Method as defined by Kollmann [55], Verification and sizing.
- Method as defined in DIN 7190-2 (2013)

Figure 33.1: Basic data: Conical interference fit
Cone angle: The cone angle is the angle β between the flank of the cone and its axis. The opening angle α of the cone is twice the size of the angle of taper.
Calculating the conical interference fit:
Adhesive coefficient in the case of slipping in the axial direction: Coefficient of friction (for slipping in axial direction) after investigations by Galle (see Kollmann [55], Table 2.20):
Material pairing |
Previous |
Coefficient for sticktion |
|
Rating |
|
Ck60/16MnCr5 |
- |
0.299 |
42CrMo4/16MnCr5 |
- |
0.269 |
31CrMoV9/31CrMoV9 |
- |
0.247 |
Ck60/16MnCr5 |
U |
0.407 |
42CrMo4/16MnCr5 |
U |
0.297 |
31CrMoV9/16MnCr5 |
U |
0.375 |
31CrMoV9/31CrMoV9 |
U |
0.468 |
Ck60/16MnCr5 |
W |
0.357 |
42CrMo4/16MnCr5 |
W |
0.472 |
31CrMoV9/31CrMoV9 |
W |
0.387 |
Load classifications:
- |
none |
U |
Circumferential bending load |
W |
Fatigue torsion load |
No adhesive coefficients for other combinations of materials are available, so you will have to estimate them.
Adhesive coefficients for radial interference fits in longitudinal and peripheral direction subjected to sliding: Coefficient of friction as described in DIN 7190 [29], Table 4, see Cylindrical interference fit section.