Previous Icon 3

Next Icon 3

Enter safeties

Click on this checkbox to set required safety values on the right-hand side of the Calculation group. Alternatively, click the button to open the Define safeties dialog window, in which you can specify safeties as defined in FKM.

The safety factors for the static strength calculation, jm (for overload failure) and jp (for deformation), are determined in accordance with section 1.5 of the Guideline, and the safety factor for fatigue resistance, jD, is determined in accordance with Part 2.5 of the Guideline. You will find detailed comments in the guideline.

 

Steel

 

jm = 2.0

jp = 1.5

jF = 1.5

jF = 1.5

GS, GJS

-not checked

jm = 2.8

jp = 2.1

jG*jF = 2.6

jG*jF = 2.6

 

-non-destruction tested

jm = 2.5

jp = 1.9

jG*jF = 2.4

jG*jF = 2.4

GJL, GJM

-not checked

jm = 3.3

jp = 2.6

jG*jF = 3.1

jG*jF = 3.1

 

-non-destruction tested

jm = 3.0

jp = 2.4

jG*jF = 2.9

jG*jF = 2.9

 

 

 

 

 

 

jm, jp: The values apply for

-

severe damage as the result of failure

 

-

high probability of load occurrence

If only minor damage results from the fracture, the safety factors can be reduced by about 15%. Provided the probability of the same load occurring again is low, the safety factors can be reduced by about 10%.

jG*jF: The values apply for

- severe damage as the result of failure

 

- irregular inspection

If only minor damage results from the fracture, the safety factors can be reduced by about 15%. Provided inspections are carried out regularly, safety factors can be reduced by about 10%.