Previous Icon 3

Next Icon 3

Materials

The materials displayed in the drop-down lists are taken from the materials database. If you cannot find the material you require in this list, you can either select Own input from the list or enter the material in the database first. Click the button next to the materials drop-down list to open the Define material, Gear 1(2) window, in which you can select the material you require from the database list of available materials. Select the Own input option to enter specific material characteristics. This option corresponds to the Create a new entry window in the database tool.

Strength calculation with normal gear materials:

The cylindrical gear strength calculation formulae defined in ISO 6336, DIN 3990 or AGMA 2001 only involve specific (most commonly used) materials and treatment methods: These are:

 

Strength calculation with unusual gear materials (not taken into account in standards):

KISSsoft handles these materials in the same way as heat treatable steels. This affects a range of less important values that are used to calculate the permitted tooth root and flank strength: factors YNT, YdrelT, YRrelT, YX, ZNT. The endurance limit values σFlim and σHlim must either be measured or already be known. The S-N curve (Woehler lines) must be defined and used to achieve more accurate calculations.

Plastics

The strength of plastic gears can be calculated either according to Niemann VDI 2545 or VDI 2736. The material properties (Young's modulus etc.) and the permitted tooth root and flank stresses are greatly affected by the temperature and the type of lubrication. This is why calculating the characteristics for plastic gears requires so much time, effort and experience, especially if only very little material data is available. VDI guideline 2736 lists the tooth root and flank strengths for a number of basic materials:

Materials manufacturers also provide gear data that can be used to calculate the strength of plastic gears. If requested, KISSsoft can also provide the relevant material files.

KISSsoft users can also add their own material data to the plastics database. The corresponding DAT file contains specific data for each material. The user can then edit the DAT files to calculate plastic gears using the values for their own materials.

As defining the permitted root and flank limiting values takes so much time and effort, and because these values are often not present, KISSsoft can also perform the calculation using a limited data volume (for example, static calculations).
As additional information, the name of the plastic includes an overview of the data that is available for calculating plastic gears.

The data used to calculate plastic gears is available in this format: [S B Fog Wd].


Abbreviations used here:

S - the ultimate or yield material strength of the material is provided for calculating static root strength

B - S-N curves (Woehler lines) are provided for calculating the root endurance limit

F - S-N curves (Woehler lines) for all lubricant types are provided for calculating the tooth flank endurance limit

Fo - S-N curve (Woehler lines) for oil lubrication are provided for calculating the tooth flank endurance limit

Fg - S-N curves (Woehler lines) for grease lubrication are provided for calculating the tooth flank endurance limit

Fd - S-N curves (Woehler lines) for a dry run are provided for calculating the tooth flank endurance limit

Fog - S-N curves (Woehler lines) for oil and grease lubrication are provided for calculating the tooth flank

W - Wear coefficients for all types of lubrication are provided for calculating wear

Wo - Wear coefficients for oil lubrication are provided for calculating wear

Wg - Wear coefficients for grease lubrication are provided for calculating wear

Wd - Wear coefficients for a dry run are provided for calculating wear

WORM - S-N curves (Woehler lines) are provided for calculating the root endurance limit for crossed helical gears

Note:

When a calculation method according to Niemann or VDI is selected, the tooth root, tooth root and wear are calculated automatically, if the data for the calculation is present. If no data is present for one or more of these methods, only the calculations for which data is available are actually performed.

Converting hardness to endurance limit values σHlim, σFlim

When you enter data for your own material, the hardness can be taken for conversion into the endurance limit values σHlim, σFlim. To open the conversion dialog, click the appropriate conversion button next to the input fields for the endurance limit values σHlim, σFlim. The data is converted in accordance with the ISO 6336-5:2003 formula described in section 5.

(The data for forged steels is used for "unalloyed/through hardened" and "alloyed/through hardened" heat treatable steels.)

σHlim, σFlim=A*x+B

x: Hardness value in the unit used in the table (depending on the HV or HBW material type)

A,B: Factors for the particular material type and processing. (from Table 1, ISO 6336-5)

Figure 14.6: Convert endurance limit values dialog window

Values for σHlim and σFlim that are required for the conversion specified in ISO 6336-5 are displayed directly in the material screen under "Own input" if these values are possible with the specified hardness and material type.

In the next conversion dialog, click on another conversion button next to the hardness input field to start converting the hardness value. In the case of materials that are not alloys you can calculate the hardness from the tensile strength value or other hardness values.

Shot peened gear

"Shot peened" only affects the alternating bending factor YM if this is calculated according to ISO 6336-1, Appendix B. This information is primarily required for documentation purposes, so that this data can be added to drawings. It is well known that shot peening improves the root safety factor. Until now, the standards for gear strength have not included any suitable data. However, if measurements have shown the extent to which σFlim is increased by shot peening, this effect can be taken into account either with the technology factor YT or by increasing σFlim.