The TMS IntraWeb Security System 1.8.5.0
========================================

Contents:
---------

1) Welcome, and thanks!
2) Installing the components
3) Release Notes for Version 1.8.5.0
4) Update History
5) Orders
6) Copyright
7) Disclaimer of Warrantee


1) Welcome and thanks!
----------------------

Welcome to the TMS IntraWeb Security System! Thanks for your interest in our
system, and we hope that it becomes a powerful addition to your toolkit!
If you have any questions, suggestions or problems, feel free to contact
us at help@tmssoftware.com.


2) Installing the components
----------------------------

NOTE: 
FOR ADDITIONAL QUESTIONS: see http://www.tmssoftware.com/site/support.asp
AND http://www.tmssoftware.com/site/faq.asp


PLEASE PERFORM ALL STEPS LISTED!


1) Open a COMMAND prompt in Windows in folder where software is installed


2) Set build variables by executing following .BAT files

   for RAD Studio 2009:
   "c:\Program Files (x86)\CodeGear\RAD Studio\6.0\bin\rsvars.bat"
 
   for RAD Studio 2010:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\7.0\bin\rsvars.bat"

   for RAD Studio XE:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\8.0\bin\rsvars.bat"

   for RAD Studio XE2:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\9.0\bin\rsvars.bat"
 
   for RAD Studio XE3:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\10.0\bin\rsvars.bat"

   for RAD Studio XE4:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\11.0\bin\rsvars.bat"

   for RAD Studio XE5:
   "c:\Program Files (x86)\Embarcadero\RAD Studio\12.0\bin\rsvars.bat"

   for RAD Studio XE6:
   "c:\Program Files (x86)\Embarcadero\Studio\14.0\bin\rsvars.bat"

   for RAD Studio XE7:
   "c:\Program Files (x86)\Embarcadero\Studio\15.0\bin\rsvars.bat"

   for RAD Studio XE8:
   "c:\Program Files (x86)\Embarcadero\Studio\16.0\bin\rsvars.bat"

   for RAD Studio 10 Seattle:
   "c:\Program Files (x86)\Embarcadero\Studio\17.0\bin\rsvars.bat"

   for RAD Studio 10.1 Berlin:
   "c:\Program Files (x86)\Embarcadero\Studio\18.0\bin\rsvars.bat"

   for RAD Studio 10.2 Tokyo:
   "c:\Program Files (x86)\Embarcadero\Studio\19.0\bin\rsvars.bat"


3) Set correct include file

   IntraWeb 10:  Rename TMSDEFS10.INC to TMSDEFS.INC
   IntraWeb 11:  Rename TMSDEFS11.INC to TMSDEFS.INC
   IntraWeb 12.0.x: Rename TMSDEFS12.inc to TMSDEFS.INC 
   IntraWeb 12.1.x: Rename TMSDEFS121.inc to TMSDEFS.INC 
   IntraWeb 12.2.x: Rename TMSDEFS122.inc to TMSDEFS.INC
   IntraWeb 14.0.x: Rename TMSDEFS140.inc to TMSDEFS.INC
 
    
4) Build package files by executing MSBUILD:

   Using following suffixes for package files depending on RAD Studio version:

   RAD Studio 2009: xx -> 2009
   RAD Studio 2010: xx -> 2010
   RAD Studio XE: xx -> 2011
   RAD Studio XE2: xx -> XE2
   RAD Studio XE3: xx -> XE3
   RAD Studio XE4: xx -> XE4
   RAD Studio XE5: xx -> XE5
   RAD Studio XE6: xx -> XE6
   RAD Studio XE7: xx -> XE7
   RAD Studio XE8: xx -> XE8
   RAD Studio 10 Seattle: xx -> XE9
   RAD Studio 10.1 Berlin: xx -> XE10
   RAD Studio 10.2 Tokyo: xx -> XE11

   IntraWeb 10.0.x / RAD Studio 2009 - 2010

   msbuild TSSCoreDxx.dproj
   msbuild IW10TSSUIDxx.dproj


   IntraWeb 11.0.x / RAD Studio 2009 - XE

   msbuild TSSCoreDxx.dproj
   msbuild IW11TSSUIDxx.dproj


   IntraWeb 12.x.x / RAD Studio 2009 - XE4

   msbuild TSSCoreDxx.dproj
   msbuild IW12TSSUIDxx.dproj


   IntraWeb 14.0.0 / RAD Studio XE3 - 10.2 Tokyo

   msbuild TSSCoreDxx.dproj
   msbuild IW14TSSUIDxx.dproj


   IntraWeb 14.0.x / RAD Studio 2009 - XE2

   msbuild TSSCoreDxx.dproj
   msbuild IW14TSSUIDxx.dproj


   IntraWeb 14.0.x / RAD Studio XE3 - 10.2 Tokyo

   msbuild TSSCoreDxx.dproj
   msbuild IW14TSSUIDxxUPD.dproj


5) Install Packages in the IDE

 
   From the IDE select "Component>Install Packages...>Add..."
   and add each of the .BPL files that were generated by executing msbuild in step 4)

   BPL file locations:

   RAD Studio 2009: 
   C:\Users\Public\Documents\RAD Studio\6.0\Bpl

   RAD Studio 2010: 
   C:\Users\Public\Documents\RAD Studio\7.0\Bpl

   RAD Studio XE: 
   C:\Users\Public\Documents\RAD Studio\8.0\Bpl

   RAD Studio XE2: 
   C:\Users\Public\Documents\RAD Studio\9.0\Bpl

   RAD Studio XE3: 
   C:\Users\Public\Documents\RAD Studio\10.0\Bpl

   RAD Studio XE4: 
   C:\Users\Public\Documents\RAD Studio\11.0\Bpl

   RAD Studio XE5: 
   C:\Users\Public\Documents\RAD Studio\12.0\Bpl

   RAD Studio XE6: 
   C:\Users\Public\Documents\Studio\14.0\Bpl

   RAD Studio XE7: 
   C:\Users\Public\Documents\Studio\15.0\Bpl

   RAD Studio XE8: 
   C:\Users\Public\Documents\Studio\16.0\Bpl

   RAD Studio 10 Seattle: 
   C:\Users\Public\Documents\Studio\17.0\Bpl

   RAD Studio 10.1 Berlin: 
   C:\Users\Public\Documents\Studio\18.0\Bpl

   RAD Studio 10.2 Berlin: 
   C:\Users\Public\Documents\Studio\19.0\Bpl


6) Add the folder where the components are located to the IDE library path
(include & resource path for C++Builder)



3) Release Notes for Version 1.8.5.0
------------------------------------

- The TMS IntraWeb Security System is compatible with 
Delphi 2009,2010,XE,XE2,XE3,XE4,XE5,XE6,XE7,XE8,10 Seattle,10.1 Berlin,10.2 Tokyo
C++Builder 2009,2010,XE,XE2,XE3,XE4,XE5,XE6,XE7,XE8,10 Seattle,10.1 Berlin,10.2 Tokyo
- While the user password is encrypted, you still need to use table-level encryption in order to ensure tight security.


4) Update History
-----------------

v1.8.5.0
  - New: Support for Delphi 10.2 Tokyo & C++Builder 10.2 Tokyo

v1.8.4.0
  - New: Support for IntraWeb 14.1.4
  - Improved: Support for databases with limited boolean field support
  - Fixed: Issue with handling group permissions

v1.8.3.0
  - New: Support for Delphi 10.1 Berlin & C++Builder 10.1 Berlin

v1.8.2.0
  - New: Support for Delphi 10 Seattle & C++Builder 10 Seattle

v1.8.1.0
  - New: Support for Delphi XE8 & C++Builder XE8

v1.8.0.1
  - New : Packages for Delphi XE7 with IW 14.0.x

v1.8.0.0
  - New: Support for Delphi XE7 & C++Builder XE7

v1.7.1.0
  - New : Support for non-default IW 14 versions in Delphi XE6 & C++Builder XE6

v1.7.0.0
   - New: Support for Delphi XE6 & C++Builder XE6

v1.6.0.0
   - New: Support for Delphi XE5 & C++Builder XE5

v1.5.0.0
   - New: Support for Delphi XE4 & C++Builder XE4
   - New: Support for IntraWeb 12.2.x
   - New: Support for IntraWeb 14.0.x

v1.4.0.0
   - Support for RAD Studio XE3
   - Support for Intraweb 14

v1.3.0.0
   - Support for Intraweb 12.1

v1.2.0.0
   - RAD Studio XE2 support

v1.1.0.0
   - Added support for IntraWeb 11
   - Added support for RAD Studio XE
   - Fixed : issue with group permission handling

v1.0.0.1
   - Fixed : small issue with collaps all/expand all popup menu in policy dialog
   - Support for Delphi 2010 & C++Builder 2010 added

v1.0.0.0
   - First release


5) Orders
---------
Use of the components in your applications requires a license. With
a license, no additional runtime royalty fees have to be paid.
A license can be obtained upon registration for the TMS IntraWeb Security System
online from http://www.tmssoftware.com/go/?tiwss or
http://www.tmssoftware.com/go/?orders


6) Copyright
------------

TMS IntraWeb Security System is (c) Copyright 2008 - 2017, TMS software.
The entire package, including source, binaries, demos, and this file, are covered
under this copyright.


7) Disclaimer of Warrantee
--------------------------

NO WARRANTIES.  TMS software expressly
disclaims any warranty for the TMS IntraWeb Security System (SOFTWARE COMPONENT
PRODUCT(S)).  THE SOFTWARE COMPONENT PRODUCT(S) AND ANY RELATED
DOCUMENTATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, 
EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION,
THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR 
PURPOSE, OR NONINFRINGEMENT.  THE ENTIRE RISK ARISING OUT OF USE OR
PERFORMANCE OF THE SOFTWARE COMPONENT PRODUCT(S) REMAINS WITH YOU. 
To the maximum extent permitted by applicable law, in no event shall
TMS software be liable for any special, incidental, indirect, or 
consequential damages whatsoever (including, without limitation, 
damages for loss of business profits, business interruption, loss of
business information, or any other pecuniary loss) arising out of the
use of or inability to use the SOFTWARE COMPONENTb PRODUCT(S) or the 
provision of or failure to provide Support Services, even if TMS software
has been advised of the possibility of such damages. 